Up to top level
AO15   AO16   AO17   AO18   AO19   Backgrounds   Calibration   Conference   Data   Docs   EPICMOS   EPICpn   Feedback   Gallery   Misc   OM   Pending   PhD_Theses   Publications   RGS   RadMonitor   SAS_Hardware   SAS_WS   SASv16.0   SASv16.0_Installation   SASv16.1   SASv16.1_Installation   SASv17.0   SASv17.0_Installation   SASv18.0   SASv18.0_Installation   SciSim   Simulators_other   Suggestions   Trash   Visibility   XMM-bouncing   XMM-news   XRPS   XSA   esas   incoming  

Logged in as guest

Viewing esas/47517
Full headers

From: aszostek@slac.stanford.edu
Subject: mos-spectra - evselect - farith
Compose reply
Download message
Move To:
1 replies: 1
1 followups: 1

Private message: yes  no

Notes:

Notification:


Date: Wed, 9 Mar 2011 02:28:03 GMT
From: aszostek@slac.stanford.edu
To: xmmhelp@sciops.esa.int
Cc: aszostek@slac.stanford.edu
Subject: mos-spectra - evselect - farith
Full_Name: Anna Szostek
Submission from: (NULL) (198.129.219.115)


Hello,
I am analyzing data with id 0610980101 with v11 of sas - extended source
analysis. I cleaned data as described in the extended source manual and while
running mos-spectra I get an error below. Is the error in farith related to
DssFitsWrite? I read that DssFitsWrite means that: 

"The data subspace indexing has become to large to fit into keywords of the from
nDSVALn (keywords can be on more than 8 characters). Thus no filter information
can be written to the FITS header for the filter in question. 
corrective action: No data subspace information is written for the given
filter."

However I don't understand what it means.Is it dangerous?  How can I fix that?

Best wishes
Anna

ERROR message:

(eveselect warning below repeated multiple times)

** evselect: warning (DssFitsWrite), The data subspace specification has become
too complex(component 24, filter 10) to be able to write using the FITS keyword
conventions. The data subspace information stored in the FITS files will be
incomplete.
farith mos1S002-im1-350-2000.fits mos1S002-mask-im-350-2000-ccd1.fits
mos1S002-im1-350-2000-mask.fits MUL copyprime=yes 
   
farith4.3 : Error Status Returned :  302
farith4.3 : column number < 1 or > tfields

farith4.3 :  ***** FITSIO Error Stack Dump *****
Specified column number is out of range: 2
  There are 0 columns in this table.
mv mos1S002-im1-350-2000-mask.fits mos1S002-im1-350-2000.fits 
   
mv: mos1S002-im1-350-2000-mask.fits: No such file or directory

(the mos-spectra run continues)


Reply 1

Resend
From: Ignacio de la Calle <xmmhelp@sciops.esa.int>
To: aszostek@slac.stanford.edu
Subject: Re: mos-spectra - evselect - farith (PR#47517)
Date: Wed Mar  9 14:57:54 2011
Dear Anna,

The eveselect message is just a warning. 

The error could be related to the way SAS v11 treats now the masks. Without
going into the details, shortly after the release of SAS v11, we found that 
ESAS had not taken into account this change. This has been fixed now and is 
ready to be released. The patch should come out within the next few days.
The error you get seems to be related to this. I would recommend to wait a 
few days until the patch is released and then try again and let us know if
you still have problems.

Regarding the other error you reported, we have an answer from the ESAS
developers as to what might be the cause of the problem. I will reply
to the corresponding email once I put all the information together.

Sorry for the inconvenience and thanks for your patient.

Regards,

Ignacio de la Calle
XMM-Newton SOC


> Full_Name: Anna Szostek
> Submission from: (NULL) (198.129.219.115)
> 
> 
> Hello,
> I am analyzing data with id 0610980101 with v11 of sas - extended source
> analysis. I cleaned data as described in the extended source manual and
while
> running mos-spectra I get an error below. Is the error in farith related
to
> DssFitsWrite? I read that DssFitsWrite means that: 
> 
> "The data subspace indexing has become to large to fit into keywords of the
from
> nDSVALn (keywords can be on more than 8 characters). Thus no filter
information
> can be written to the FITS header for the filter in question. 
> corrective action: No data subspace information is written for the given
> filter."
> 
> However I don't understand what it means.Is it dangerous?  How can I fix
that?
> 
> Best wishes
> Anna
> 
> ERROR message:
> 
> (eveselect warning below repeated multiple times)
> 
> ** evselect: warning (DssFitsWrite), The data subspace specification has
become
> too complex(component 24, filter 10) to be able to write using the FITS
keyword
> conventions. The data subspace information stored in the FITS files will
be
> incomplete.
> farith mos1S002-im1-350-2000.fits mos1S002-mask-im-350-2000-ccd1.fits
> mos1S002-im1-350-2000-mask.fits MUL copyprime=yes 
>    
> farith4.3 : Error Status Returned :  302
> farith4.3 : column number < 1 or > tfields
> 
> farith4.3 :  ***** FITSIO Error Stack Dump *****
> Specified column number is out of range: 2
>   There are 0 columns in this table.
> mv mos1S002-im1-350-2000-mask.fits mos1S002-im1-350-2000.fits 
>    
> mv: mos1S002-im1-350-2000-mask.fits: No such file or directory
> 
> (the mos-spectra run continues)
> 
> 


Followup 1

Compose reply
Download message
From: "Szostek, Anna" <aszostek@slac.stanford.edu>
To: Ignacio de la Calle <xmmhelp@sciops.esa.int>
Date: Wed, 9 Mar 2011 14:29:38 -0800
Subject: Re: mos-spectra - evselect - farith (PR#47517)
Dear Ignacio,
Thank you for the information. I will wait for the patch.

Best regards
Anna

On Mar 9, 2011, at 6:57 AM, Ignacio de la Calle wrote:

> Dear Anna,
> 
> The eveselect message is just a warning. 
> 
> The error could be related to the way SAS v11 treats now the masks. Without
> going into the details, shortly after the release of SAS v11, we found that

> ESAS had not taken into account this change. This has been fixed now and is

> ready to be released. The patch should come out within the next few days.
> The error you get seems to be related to this. I would recommend to wait a 
> few days until the patch is released and then try again and let us know if
> you still have problems.
> 
> Regarding the other error you reported, we have an answer from the ESAS
> developers as to what might be the cause of the problem. I will reply
> to the corresponding email once I put all the information together.
> 
> Sorry for the inconvenience and thanks for your patient.
> 
> Regards,
> 
> Ignacio de la Calle
> XMM-Newton SOC
> 
> 
>> Full_Name: Anna Szostek
>> Submission from: (NULL) (198.129.219.115)
>> 
>> 
>> Hello,
>> I am analyzing data with id 0610980101 with v11 of sas - extended
source
>> analysis. I cleaned data as described in the extended source manual and
while
>> running mos-spectra I get an error below. Is the error in farith
related to
>> DssFitsWrite? I read that DssFitsWrite means that: 
>> 
>> "The data subspace indexing has become to large to fit into keywords of
the
> from
>> nDSVALn (keywords can be on more than 8 characters). Thus no filter
> information
>> can be written to the FITS header for the filter in question. 
>> corrective action: No data subspace information is written for the
given
>> filter."
>> 
>> However I don't understand what it means.Is it dangerous?  How can I
fix
> that?
>> 
>> Best wishes
>> Anna
>> 
>> ERROR message:
>> 
>> (eveselect warning below repeated multiple times)
>> 
>> ** evselect: warning (DssFitsWrite), The data subspace specification
has
> become
>> too complex(component 24, filter 10) to be able to write using the FITS
> keyword
>> conventions. The data subspace information stored in the FITS files
will be
>> incomplete.
>> farith mos1S002-im1-350-2000.fits mos1S002-mask-im-350-2000-ccd1.fits
>> mos1S002-im1-350-2000-mask.fits MUL copyprime=yes 
>> 
>> farith4.3 : Error Status Returned :  302
>> farith4.3 : column number < 1 or > tfields
>> 
>> farith4.3 :  ***** FITSIO Error Stack Dump *****
>> Specified column number is out of range: 2
>>  There are 0 columns in this table.
>> mv mos1S002-im1-350-2000-mask.fits mos1S002-im1-350-2000.fits 
>> 
>> mv: mos1S002-im1-350-2000-mask.fits: No such file or directory
>> 
>> (the mos-spectra run continues)
>> 
>> 
> 
> ================================================================================================
> This message and any attachments are intended for the use of the addressee
or addressees only. The unauthorised disclosure, 
> 
> use, dissemination or copying (either in whole or in part) of its content
is not permitted. If you received this message in 
> 
> error, please notify the sender and delete it from your system. Emails can
be altered and their integrity cannot be guaranteed by   
> 
> the sender. 
> 
> Please consider the environment before printing this email.
> =================================================================================================
> 



Up to top level
AO15   AO16   AO17   AO18   AO19   Backgrounds   Calibration   Conference   Data   Docs   EPICMOS   EPICpn   Feedback   Gallery   Misc   OM   Pending   PhD_Theses   Publications   RGS   RadMonitor   SAS_Hardware   SAS_WS   SASv16.0   SASv16.0_Installation   SASv16.1   SASv16.1_Installation   SASv17.0   SASv17.0_Installation   SASv18.0   SASv18.0_Installation   SciSim   Simulators_other   Suggestions   Trash   Visibility   XMM-bouncing   XMM-news   XRPS   XSA   esas   incoming  