AO15   AO16   AO17   AO18   AO19   Backgrounds   Calibration   Conference   Data   Docs   EPICMOS   EPICpn   Feedback   Gallery   Misc   OM   Pending   PhD_Theses   Publications   RGS   RadMonitor   SAS_Hardware   SAS_WS   SASv16.0   SASv16.0_Installation   SASv16.1   SASv16.1_Installation   SASv17.0   SASv17.0_Installation   SASv18.0   SASv18.0_Installation   SciSim   Simulators_other   Suggestions   Trash   Visibility   XMM-bouncing   XMM-news   XRPS   XSA   esas   incoming  

Logged in as guest

Viewing EPICpn/49111
Full headers

From: lvming.astro@gmail.com
Subject: error related to eoiclccorr
Compose reply
Download message
Move To:
1 replies: 1
0 followups:

Private message: yes  no

Notes:

Notification:


Date: Wed, 16 Nov 2011 08:44:06 GMT
From: lvming.astro@gmail.com
To: xmmhelp@sciops.esa.int
Cc: lvming.astro@gmail.com
Subject: error related to eoiclccorr
Full_Name: Lvming
Submission from: (NULL) (59.41.252.225)


Dear,
   When I input command " eoiclccorr" to eliminate the background, an error
appeared:

** epiclccorr::arfgen: error (blockNotFound), Could not find block with
qualified name '/home/tiexue/data/top_dir/ccf/EPN_FILTERTRANSX_0014.CCF:FILTER-CALMEDIUM'
in dataset with name '/home/tiexue/data/top_dir/ccf/EPN_FILTERTRANSX_0014.CCF'
** epiclccorr: error (invalidInvocation), Execution failed of arfgen
(arfgen-1.80.1)  [xmmsas_20110223_1801-11.0.0]


 Thanks in advance !
 Best Wishes


Reply 1

Resend
From: Jan-Uwe Ness <xmmhelp@sciops.esa.int>
To: lvming.astro@gmail.com
Subject: Re: error related to eoiclccorr (PR#49111)
Date: Wed Nov 16 14:37:12 2011
Hi,

 the reason for this message is the applied filter being CALMEDIUM. While the
normal medium filter was used, an onboard calibration source was turned on,
illuminating the entire chip for calibration purposes. This limits the
scientific use of the data as the source spectrum will be contaminated by the on
board calibration source. It would be quite difficult to reconstruct the source
spectrum.

 If in spite of this limitation you deem this particular observation useful for
your scientific purposes, please let me know the ObsID so I can investigate a
workaround for the missing calibration file for the CALMEDIUM filter setting.

 Best regards,
Jan-Uwe Ness

--
XMM-Newton SOC



> Dear,
>    When I input command " eoiclccorr" to eliminate the background, an
error
> appeared:
> 
> ** epiclccorr::arfgen: error (blockNotFound), Could not find block with
> qualified name '/home/tiexue/data/top_dir/ccf/EPN_FILTERTRANSX_0014.CCF:FILTER-CALMEDIUM'
> in dataset with name
'/home/tiexue/data/top_dir/ccf/EPN_FILTERTRANSX_0014.CCF'
> ** epiclccorr: error (invalidInvocation), Execution failed of arfgen
> (arfgen-1.80.1)  [xmmsas_20110223_1801-11.0.0]
> 
> 
>  Thanks in advance !
>  Best Wishes
> 
> 

Up to top level
AO15   AO16   AO17   AO18   AO19   Backgrounds   Calibration   Conference   Data   Docs   EPICMOS   EPICpn   Feedback   Gallery   Misc   OM   Pending   PhD_Theses   Publications   RGS   RadMonitor   SAS_Hardware   SAS_WS   SASv16.0   SASv16.0_Installation   SASv16.1   SASv16.1_Installation   SASv17.0   SASv17.0_Installation   SASv18.0   SASv18.0_Installation   SciSim   Simulators_other   Suggestions   Trash   Visibility   XMM-bouncing   XMM-news   XRPS   XSA   esas   incoming  