AO15   AO16   AO17   AO18   AO19   Backgrounds   Calibration   Conference   Data   Docs   EPICMOS   EPICpn   Feedback   Gallery   Misc   OM   Pending   PhD_Theses   Publications   RGS   RadMonitor   SAS_Hardware   SAS_WS   SASv16.0   SASv16.0_Installation   SASv16.1   SASv16.1_Installation   SASv17.0   SASv17.0_Installation   SASv18.0   SASv18.0_Installation   SciSim   Simulators_other   Suggestions   Trash   Visibility   XMM-bouncing   XMM-news   XRPS   XSA   esas   incoming  

Logged in as guest

Viewing EPICMOS/17854
Full headers

From: gjmluna@astro.iag.usp.br
Subject: lccorr in SAS6.1
Compose reply
Download message
Move To:
2 replies: 1 2
1 followups: 1

Private message: yes  no

Notes:

Notification:


Date: Thu, 19 May 2005 14:31:01 GMT
From: gjmluna@astro.iag.usp.br
To: xmmhelp@xmm.vilspa.esa.es
CC: gjmluna@astro.iag.usp.br
Subject: lccorr in SAS6.1
Full_Name: Gerardo Luna
Submission from: (NULL) (143.107.18.118)


Hello: I'm running the lccorr task on my lightcurves and I get the next error
message:

** lccorr: error (attributableNotFound), Could not find attribute with qualified
name temp_output_ts.ds:RATE%TIMEZERO in attributable set RATE

My command line was the following:

lccorr  eventset=${root}clean_evt.fits 
srctsset=${root}_${inst}_lc_source_${eini}_${eend}.fits \
withbkgtsset=yes bkgtsset=${root}_${inst}_lc_back_${eini}_${eend}.fits \
outset=${root}_${inst}_lc_${bin}_corrigida_${eini}_${eend}.fits treatvignet=yes
treatfiltertrans=yes \
treatquantumeff=yes treatcosmicrays=yes treatdeadtime=yes treatgti=yes \
applycorrections=yes srcposstyle=user \
srcra=123.551 srcdec=-41.7081 efrac=0.95

the same happens with MOS1, MOS2 and PN cameras

thanks you and best regards
Gerardo


Reply 1

Resend
From: Nora Loiseau <xmmhelp@xmm.vilspa.esa.es>
To: gjmluna@astro.iag.usp.br
Subject: Re: lccorr in SAS6.1 (PR#17854)
Date: Thu May 19 16:53:10 2005
Dear Gerardo,

could you inform us on which data are you working (obsID number) so
we can try to reproduce your problem?

Best regards,

Nora
----
Dr. Nora Loiseau
XMM-Newton User Support Group


Followup 1

Compose reply
Download message
Date: Thu, 19 May 2005 14:14:45 -0300 (ART)
From: juan luna <gjmluna@yahoo.com>
Subject: Re: lccorr in SAS6.1 (PR#17854)
To: Nora Loiseau <xmmhelp@xmm.vilspa.esa.es>
Dear Nora: the Obs ID is:


0153350101

thanks you
Gerardo



Gerardo Juan Manuel Luna

__________________________________________________
Correo Yahoo!
Espacio para todos tus mensajes, antivirus y antispam .gratis! 
.Abr. tu cuenta ya! - http://correo.yahoo.com.ar



Reply 2

Resend
From: Nora Loiseau <xmmhelp@xmm.vilspa.esa.es>
To: gjmluna@astro.iag.usp.br
Subject: Re: lccorr in SAS6.1 (PR#17854)
Date: Fri May 27 17:05:42 2005
Dear Gerardo,

the lccorr problem is a recent bug (see message PR#17513 in helpdesk) that has
been fixed for the next SAS release. In the meantime you can use some other tool
outside SAS to correct your lightcurve (IDL or FTOOLS).

We are sorry for the inconvenience,

Best regards,

Nora
----
Dr. Nora Loiseau
XMM-Newton User Support Group

Up to top level
AO15   AO16   AO17   AO18   AO19   Backgrounds   Calibration   Conference   Data   Docs   EPICMOS   EPICpn   Feedback   Gallery   Misc   OM   Pending   PhD_Theses   Publications   RGS   RadMonitor   SAS_Hardware   SAS_WS   SASv16.0   SASv16.0_Installation   SASv16.1   SASv16.1_Installation   SASv17.0   SASv17.0_Installation   SASv18.0   SASv18.0_Installation   SciSim   Simulators_other   Suggestions   Trash   Visibility   XMM-bouncing   XMM-news   XRPS   XSA   esas   incoming  