AO15   AO16   AO17   AO18   AO19   Backgrounds   Calibration   Conference   Data   Docs   EPICMOS   EPICpn   Feedback   Gallery   Misc   OM   Pending   PhD_Theses   Publications   RGS   RadMonitor   SAS_Hardware   SAS_WS   SASv16.0   SASv16.0_Installation   SASv16.1   SASv16.1_Installation   SASv17.0   SASv17.0_Installation   SASv18.0   SASv18.0_Installation   SciSim   Simulators_other   Suggestions   Trash   Visibility   XMM-bouncing   XMM-news   XRPS   XSA   esas   incoming  

Logged in as guest

Viewing AO16/80245
Full headers

From: jgrindlay@cfa.harvard.edu
Subject: error on Observation page for Proposal
Compose reply
Download message
Move To:
1 replies: 1
0 followups:

Private message: yes  no

Notes:

Notification:


Date: Fri, 7 Oct 2016 08:14:39 GMT
From: jgrindlay@cfa.harvard.edu
To: xmmhelp@sciops.esa.int
CC: jgrindlay@cfa.harvard.edu
Subject: error on Observation page for Proposal
Full_Name: Jonathan Grindlay
Submission from: (NULL) (173.76.35.170)


I am getting an error on Observation page for the proposal I want to submit.
Error is

Observation #1: Prime Instrument Mode (RGS): Prime Instrument=RGS must be
specified

But I have NOT selected RGS for my Prime instrument. I have selected Epic

What am I doing wrong? I am not able to submit until this is fixed and the
scientific justification is long finished.

Help!

Pls. reply soon.

Thanks, Josh Grindlay


Reply 1

Resend
From: Rosario Gonzalez Riestra <xmmhelp@sciops.esa.int>
To: jgrindlay@cfa.harvard.edu
Subject: Re: error on Observation page for Proposal (PR#80245)
Date: Fri Oct  7 08:19:31 2016
Dear Dr. Grindlay ,

You have to select the "Prime Instrument" (and the "Prime Instrument Mode" in
the drop-box menus in the Observation Page, just below the target coordinates.

Regards

Rosario Gonzalez-Riestra
XMM-SOC User Support Group

> Full_Name: Jonathan Grindlay
> Submission from: (NULL) (173.76.35.170)
> 
> 
> I am getting an error on Observation page for the proposal I want to
submit.
> Error is
> 
> Observation #1: Prime Instrument Mode (RGS): Prime Instrument=RGS must be
> specified
> 
> But I have NOT selected RGS for my Prime instrument. I have selected Epic
> 
> What am I doing wrong? I am not able to submit until this is fixed and the
> scientific justification is long finished.
> 
> Help!
> 
> Pls. reply soon.
> 
> Thanks, Josh Grindlay
> 
> 

Up to top level
AO15   AO16   AO17   AO18   AO19   Backgrounds   Calibration   Conference   Data   Docs   EPICMOS   EPICpn   Feedback   Gallery   Misc   OM   Pending   PhD_Theses   Publications   RGS   RadMonitor   SAS_Hardware   SAS_WS   SASv16.0   SASv16.0_Installation   SASv16.1   SASv16.1_Installation   SASv17.0   SASv17.0_Installation   SASv18.0   SASv18.0_Installation   SciSim   Simulators_other   Suggestions   Trash   Visibility   XMM-bouncing   XMM-news   XRPS   XSA   esas   incoming  

Logged in as guest


Please make your (short) question the subject of your request!


Web interface using JitterBug ... back to the XMM home page