Up to top level
AO15   AO16   AO17   AO18   AO19   Backgrounds   Calibration   Conference   Data   Docs   EPICMOS   EPICpn   Feedback   Gallery   Misc   OM   Pending   PhD_Theses   Publications   RGS   RadMonitor   SAS_Hardware   SAS_WS   SASv16.0   SASv16.0_Installation   SASv16.1   SASv16.1_Installation   SASv17.0   SASv17.0_Installation   SASv18.0   SASv18.0_Installation   SciSim   Simulators_other   Suggestions   Trash   Visibility   XMM-bouncing   XMM-news   XRPS   XSA   esas   incoming  

Logged in as guest

Viewing AO16/80215
Full headers

From: rwr@stanford.edu
Subject: Does a non-standard OM monitor require 'multiple filter rotations'?
Compose reply
Download message
Move To:
1 replies: 1
0 followups:

Private message: yes  no

Notes:

Notification:


Date: Sat, 1 Oct 2016 00:33:08 GMT
From: rwr@stanford.edu
To: xmmhelp@sciops.esa.int
CC: rwr@stanford.edu
Subject: Does a non-standard OM monitor require 'multiple filter rotations'?
Full_Name: Roger W. Romani
Submission from: (NULL) (171.64.109.18)


Greetings, I have a program where the science requires OM context
monitoring in a single filter (U). This is not the default OM filter
sequence, but during the (100ks) observation it does not request
any filter rotations. Do I need to flag this as 
"multiple filter wheel rotations" on RPS?
The scientific need for this sequence is already described in the 
proposal text.


Reply 1

Resend
From: Pedro M. Rodriguez Pascual <xmmhelp@sciops.esa.int>
To: rwr@stanford.edu
Subject: Re: Does a non-standard OM monitor require 'multiple filter rotations'? (PR#80215)
Date: Sat Oct  1 14:57:31 2016
Hi Roger, 

for multiple exposures through just one OM filter you do not need to request
multiple OM filter wheel rotations. Please, set that field to N in the cover
page form.


Pedro



> Full_Name: Roger W. Romani
> Submission from: (NULL) (171.64.109.18)
> 
> 
> Greetings, I have a program where the science requires OM context
> monitoring in a single filter (U). This is not the default OM filter
> sequence, but during the (100ks) observation it does not request
> any filter rotations. Do I need to flag this as 
> "multiple filter wheel rotations" on RPS?
> The scientific need for this sequence is already described in the 
> proposal text.
> 
> 

Up to top level
AO15   AO16   AO17   AO18   AO19   Backgrounds   Calibration   Conference   Data   Docs   EPICMOS   EPICpn   Feedback   Gallery   Misc   OM   Pending   PhD_Theses   Publications   RGS   RadMonitor   SAS_Hardware   SAS_WS   SASv16.0   SASv16.0_Installation   SASv16.1   SASv16.1_Installation   SASv17.0   SASv17.0_Installation   SASv18.0   SASv18.0_Installation   SciSim   Simulators_other   Suggestions   Trash   Visibility   XMM-bouncing   XMM-news   XRPS   XSA   esas   incoming  

Logged in as guest


Please make your (short) question the subject of your request!


Web interface using JitterBug ... back to the XMM home page